CPQ Medicine (2019) 8:1
Conceptual Paper

Why We Still Cannot Answer Clearly If Low-Intensity Pulsed Ultrasound Treatment Can Repair Articular Cartilage?


Ioannis Manousakas

Department of Biomedical Engineering, I-Shou University, Taiwan

*Correspondence to: Dr. Ioannis Manousakas, Department of Biomedical Engineering, I-Shou University, Taiwan.

Copyright © 2019 Dr. Ioannis Manousakas. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Received: 04 November 2019
Published: 26 November 2019

Keywords: Low Intensity Pulsed Ultrasound; Articular Cartilage; Treatment Protocol

Five years ago a question was raised. Is it possible for Low-intensity pulsed ultrasound treatment (LIPUS) to repair articular cartilage? A daily 20-minute treatment for 3 months was given to surgically created cartilage defects of 5mm in diameter on the right side distal femoral condyle of rabbits. The ultrasonic device used was an Exogen low-intensity pulsed ultrasound device (Smith & Nephew Inc, Memphis, TN, USA) which provided a peak intensity of 30mW/cm2 at a frequency of 1.5MHz. After treatment, the cartilage defects of the LIPUS-treated group were covered by proliferative tissue, where the non-treated were not. The study concluded that there was no significant therapeutic effect.

In a recent similar type study, the treatment was for 10 min per day for 14 days at 1W/cm2 at a frequency of 1MHz (the ultrasonic device was not disclosed). This study suggested that LIPUS has therapeutic potential for the treatment of mandibular condylar cartilage defects of 2mm in diameter. In [12], normal and osteoarthritis chondrocytes in culture dishes were treated with 3MHz ultrasound for 6 days, 20 min per day at intensities of 20, 30, 40 and 50mW/cm2. In [1], a frequency of 1MHz, with an intensity of 0.1 W/ cm2 was used on human osteoarthritic knee showed no significant difference in the treatment effect. In [4] 1MHz with a peak intensity of 1W/cm2 at a 20% duty cycle was applied for cartilage repair in humans. In this study it is mentioned that there is limited understanding about the important factors that may influence the effects of the treatment, such as dose, intensity, mode, or application techniques. A previous metaanalysis study [5] was inconclusive. Human chondrocytes and explants were exposed to LIPUS (30mW/ cm2; 20min/day, 6 days) in [2]. Li et al [3] used 3MHz ultrasound with 20% duty cycle and 30mW/cm2 acoustic intensity for 20 min a day, 5days a week for a total of 6weeks. This study concluded that low intensity ultrasound could improve cartilage degeneration. Chondrocytes in culture dish treated with LIPUS for 20 min at 3.0MHz frequency and 60mW/cm2 intensity showed increased gene expressions [8]. A review article state that LIPUS increases proliferation in articular cartilage [7] and state that the desired biological effect depends on the type of signal used. Oyonarte et al concluded that LIPUS (30mW/cm2 1MHz, 5 times a week over a 26-day period) may alter the histology of cartilage when treated for 10 or 20 min and the sensitivity of condylar tissues to LIPUS stimulation differs between the anterior and posterior regions of the condyle, and will also depend on the duration of daily stimulation. Also Sahu et al [10] concluded that continuous ultrasound at 5MHz (intensity < 20mWcm-2) for 20 min 4 times per day for 28 days improved cartilage repair and also claim that the bio-effects are frequency dependent. Cyclic tensile strain has shown by Yank et al to have no therapeutic effects on normal articular cartilage and chondrocytes [15] Xia et al exposed to LIPUS New Zealand White rabbits with osteoarthritis (3MHz, 20% duty cycle,). They concluded that LIPUS protects cartilage from damage in early-stage osteoarthritis. Uddin et al [11] concludes that LIPUS (20min per day at 30mW/cm2, 1MHz, 40mW/cm2, 20 min/day 6d/wk for 5 weeks) has potential therapeutic effects in preventing cartilage degradation and treating osteoarthritis. Zhou et al also concluded that LIPUS (1MHz, 1W/cm2, 10 min, for 14 days for once a day) decreased the severity of cartilage injury [16]. Furthermore, in real life, when walking pressures in a joint are in the range from 3 to 10MPa with a frequency around 1Hz [6].

As it can be noticed, the majority of the published research shows that LIPUS has some effect on articular cartilage. But why some studies come to different conclusions? Is it really because the size of the surgically induced defects or the treatment protocol? Or is it because the type of the LIPUS device, its frequency, its intensity, all the above, or something else? Ultrasound research in Medicine and Biology suffers from the fact that are too many parameters involved. It is clear that if we want LIPUS to become a clinical practice, we all have to put some more effort on producing standardized and repeatable research with evidence on how to design treatment protocols for LIPUS.

Bibliography

  1. Kim, E. D., et al. (2019). Efficacy and Safety of a Stimulator Using Low-Intensity Pulsed Ultrasound Combined with Transcutaneous Electrical Nerve Stimulation in Patients with Painful Knee Osteoarthritis. Pain Res Manag., 2019, 7964897.
  2. Korstjens, C. M., et al. (2008). Low-intensity pulsed ultrasound affects human articular chondrocytes in vitro. Med Biol Eng Comput., 46(12), 1263-1270.
  3. Li, X., et al. (2019). Mitigation of Articular Cartilage Degeneration and Subchondral Bone Sclerosis in Osteoarthritis Progression Using Low-Intensity Ultrasound Stimulation. Ultrasound Med Biol., 45(1), 148-159.
  4. Loyola-Sanchez, A., et al. (2012). Effect of low-intensity pulsed ultrasound on the cartilage repair in people with mild to moderate knee osteoarthritis: a double-blinded, randomized, placebo-controlled pilot study. Arch Phys Med Rehabil., 93(1), 35-42.
  5. Loyola-Sanchez, A., Richardson, J. & MacIntyre, N. J. (2010). Efficacy of ultrasound therapy for the management of knee osteoarthritis: a systematic review with meta-analysis. Osteoarthritis Cartilage, 18(9), 1117-1126.
  6. Martinez-Moreno, D., et al. (2019). Cartilage biomechanics: A key factor for osteoarthritis regenerative medicine. Biochim Biophys Acta Mol Basis Dis., 1865(6), 1067-1075.
  7. Massari, L., et al. (2019). Biophysical stimulation of bone and cartilage: state of the art and future perspectives. Int Orthop., 43(3), 539-551.
  8. Nishida, T., et al. (2017). Low-intensity pulsed ultrasound (LIPUS) treatment of cultured chondrocytes stimulates production of CCN family protein 2 (CCN2), a protein involved in the regeneration of articular cartilage: mechanism underlying this stimulation. Osteoarthritis Cartilage, 25(5), 759-769.
  9. Oyonarte, R., Zarate, M. & Rodriguez, F. (2009). Low-intensity pulsed ultrasound stimulation of condylar growth in rats. Angle Orthod., 79(5), 964-970.
  10. Sahu, N., Viljoen, H. J. & Subramanian, A. (2019). Continuous low-intensity ultrasound attenuates IL-6 and TNFalpha-induced catabolic effects and repairs chondral fissures in bovine osteochondral explants. BMC Musculoskelet Disord., 20(1), 193.
  11. Uddin, S. M., et al. (2016). Chondro-protective effects of low intensity pulsed ultrasound. Osteoarthritis Cartilage, 24(11), 1989-1998.
  12. Xia, P., et al. (2015). Low-Intensity Pulsed Ultrasound Affects Chondrocyte Extracellular Matrix Production via an Integrin-Mediated p38 MAPK Signaling Pathway. Ultrasound Med Biol., 41(6), 1690-1700.
  13. Xia, P., et al. (2015). Low-Intensity Pulsed Ultrasound Treatment at an Early Osteoarthritis Stage Protects Rabbit Cartilage From Damage via the Integrin/Focal Adhesion Kinase/Mitogen-Activated Protein Kinase Signaling Pathway. J Ultrasound Med., 34(11), 1991-1999.
  14. Yang, S. W., et al. (2014). Does low-intensity pulsed ultrasound treatment repair articular cartilage injury? A rabbit model study. BMC Musculoskelet Disord., 15, 36.
  15. Yang, Y., et al. (2019). Mechanical stress protects against osteoarthritis via regulation of the AMPK/NF-kappaB signaling pathway. J Cell Physiol., 234(6), 9156-9167.
  16. Zhou, H. Y., et al. (2019). Low-intensity pulsed ultrasound repair in mandibular condylar cartilage injury rabbit model. Arch Oral Biol., 104, 60-66.

Total Articles Published

8
9
2


Total Citations:

1
8
4




Highlights


Cient Periodique is a ‘Gold’ open access publisher that aspires to offer absolute free, unrestricted access to the valuable research information

We welcome all the eminent authors to submit your valuable paper

Cient Periodique invites the participation of honourable Editors and Authors

CPQ Journals provide Certificates for publication

Cient Periodique also offers memberships for potential Authors

Best Articles will be appreciated with the provision of corresponding Certificate

Hi!

We're here to answer your questions!


Send us a message via Whatsapp, and we'll reply the moment we're available!